Post-installed Rebar Connections with Injection System VME

Description

The Injection System VME for post-installed rebar connections has a European Technical Approval (ETA-07/0299). Reinforcement bars from 8 to 28 mm diameter can be fastened in regular concrete from strength class C12/15 to C50/60. As usual the reinforcement can be designed in accordance with EN 1992-1-1:2004 (EC 2). Using the Tension Anchor ZA in sizes M12, M16 and M20 steel structures can be fixed at minimum edge distance.The hole cleaning procedure for the MKT Injection System VME is much easier when hammer drilling or air drilling. Just blow the holes out using compressed air and the specific MKT cleaning tools. The reduced cleaning results in quicker installation saving labor costs.

Installer training is provided by MKT and a certificate will be issued by an independent institute, which is recognized by the DIBt.

Applications

Subsequent closing of wall- and ceiling openings, reinforcing exi- sting concrete structures, installation of reinforcement to connect successive structural members, e.g. if reinforcement has been left out or could not be cast in due to the construction sequence, connection of steel structures.

Categories: ,

Description